    Rapid Ref : 0000102482  

    Replacement filter for prefilter module BPF
    0000102482

    £163.48  EX VAT
     Buy in 3 easy interest free payments of £54.49† with

    Plymovent Spares FAQs

    Questions about replacement parts for welding fume extraction equipment: filters, hoses, clamps, dampers, flanges, mounting rails and automatic start/stop devices.

    When should a damaged extraction hose be repaired or replaced?icon-minus-redicon-plus-red

    Check hoses and hoods by eye regularly. Hoods and hoses should be replaced or repaired where there is damage or deterioration. Look for splits, crushed or kinked sections, worn spiral reinforcement, burn marks from hot work and loose cuffs.

    A hose with holes or a collapsed section leaks air and reduces the suction at the hood, so fume may escape without it being obvious. Replace the hose rather than taping a long split, and check the replacement is suitable for welding use. Parts from different makers can be used together if they are compatible and fit for the task.

    How often should fume extraction be examined, and what can I check myself?icon-minus-redicon-plus-red

    A local exhaust ventilation system must have a thorough examination and test by a competent person at regular intervals, with a record kept. Your safety adviser can confirm how often your system needs it, and some systems need it more often. This is separate from the day-to-day checks you do yourself.

    Before welding, check that the extraction is switched on and working, that hoses and hoods are undamaged, and that any airflow indicator or filter gauge reads normally. Weld fume is usually visible, so you can also judge how well it is being captured. Keep notes of checks, repairs and filter changes, and follow the manufacturer's instructions for maintenance.

    Does hose length matter, and can I add extra hose?icon-minus-redicon-plus-red

    Yes. Extra hose, bends and kinks add resistance and reduce the airflow at the hood, so use the shortest, straightest run that reaches the work. Fixed systems are best with rigid ducting and short flexible hoses, and adding hoses or closing inlets can make a system ineffective. Such a system should be designed by competent people.

    Before lengthening a hose or fitting a longer one, check the manufacturer's maximum length and that the unit has the capacity. After any change, check that the hood still captures the fume, and tell the person who carries out the examination of the system.

    How do I match a replacement hose to my extraction unit?icon-minus-redicon-plus-red

    Hoses come in different bores and are used for different types of extraction. Large-bore hoses suit high-volume systems with a big hood or arm, while small-bore hoses suit high-velocity nozzles that sit very close to the arc. The two are not interchangeable.

    Measure the hose you are replacing, or check the unit's manual or data plate, so the internal diameter, the cuff or spigot size and the length suit your system. Choose a hose rated for welding fume and heat, and keep the same bore rather than reducing it, because a narrower hose reduces airflow. Check that the new hose fits the clamps and flange you already have.