Questions about replacement parts for welding fume extraction equipment: filters, hoses, clamps, dampers, flanges, mounting rails and automatic start/stop devices.
How do I know when an extraction filter needs replacing?

Most extraction units have a gauge or indicator light that shows how clogged the filter is, because as the filter fills with fume the resistance to airflow rises and the suction at the hood falls. Many filters are cleaned by the unit's own cleaning function, and replacement is needed when cleaning no longer brings the reading back to normal.
Filters are generally replaced when they are loaded, rather than at a fixed interval, because it depends on how much welding is done. Follow the unit's manual for the correct gauge reading, cleaning method and replacement procedure. If fume is escaping the hood more than usual, check the filter first.
When should a damaged extraction hose be repaired or replaced?

Check hoses and hoods by eye regularly. Hoods and hoses should be replaced or repaired where there is damage or deterioration. Look for splits, crushed or kinked sections, worn spiral reinforcement, burn marks from hot work and loose cuffs.
A hose with holes or a collapsed section leaks air and reduces the suction at the hood, so fume may escape without it being obvious. Replace the hose rather than taping a long split, and check the replacement is suitable for welding use. Parts from different makers can be used together if they are compatible and fit for the task.
How often should fume extraction be examined, and what can I check myself?

A local exhaust ventilation system must have a thorough examination and test by a competent person at regular intervals, with a record kept. Your safety adviser can confirm how often your system needs it, and some systems need it more often. This is separate from the day-to-day checks you do yourself.
Before welding, check that the extraction is switched on and working, that hoses and hoods are undamaged, and that any airflow indicator or filter gauge reads normally. Weld fume is usually visible, so you can also judge how well it is being captured. Keep notes of checks, repairs and filter changes, and follow the manufacturer's instructions for maintenance.
If my extraction is faulty, can I keep welding with the doors open?

No. Open doors and windows usually do not remove welding fume well enough, and general ventilation on its own is not a substitute for capturing fume at source. Welding fume, including from mild steel, can cause lung cancer, and exposure should be controlled, typically with local exhaust ventilation.
If extraction cannot control the fume, suitable respiratory protective equipment is needed as well, and this is a matter for your risk assessment. A fault in a part such as a hose, filter or fan should be put right promptly. If you are unsure whether the system is still doing its job, ask a competent person to check it.
Does hose length matter, and can I add extra hose?

Yes. Extra hose, bends and kinks add resistance and reduce the airflow at the hood, so use the shortest, straightest run that reaches the work. Fixed systems are best with rigid ducting and short flexible hoses, and adding hoses or closing inlets can make a system ineffective. Such a system should be designed by competent people.
Before lengthening a hose or fitting a longer one, check the manufacturer's maximum length and that the unit has the capacity. After any change, check that the hood still captures the fume, and tell the person who carries out the examination of the system.
How do I match a replacement hose to my extraction unit?

Hoses come in different bores and are used for different types of extraction. Large-bore hoses suit high-volume systems with a big hood or arm, while small-bore hoses suit high-velocity nozzles that sit very close to the arc. The two are not interchangeable.
Measure the hose you are replacing, or check the unit's manual or data plate, so the internal diameter, the cuff or spigot size and the length suit your system. Choose a hose rated for welding fume and heat, and keep the same bore rather than reducing it, because a narrower hose reduces airflow. Check that the new hose fits the clamps and flange you already have.