    The NCW-4 is a 3-cored wire to be conducted through an extraction arm that is mounted on a mobile welding fume extractor. The NCW-4 is used to connect a working light or working light + automatic start/stop (arc sensor) which is installed in the hood of the arm, to the mobile unit.

    Brochures & Manuals

    BROCHURES & MANUALS
       View Brochure

    Related Items

    Plymovent MFD Options FAQs

    Arms, hoses, filters, lights and electrical kits for a portable welding fume extraction unit, and how to work out which ones suit yours.

    How close should an extraction arm hood be to the weld?icon-minus-redicon-plus-red

    As close as you can get it without disturbing the shielding gas or blocking your view. A portable hood captures fume only in a limited zone around its opening, so a hood held further away mostly pulls in workshop air.

    Aim it at the arc, slightly above and to the side so the rising plume is drawn away from your face, and reposition it as the weld progresses. Positioning and repositioning the hood as often as needed is part of getting good capture.

    Does a longer or more bent extraction hose reduce suction?icon-minus-redicon-plus-red

    Generally, yes. Air loses energy as it rubs along the hose wall and especially where it is forced round tight bends, so a long, kinked or crushed hose gives less airflow at the hood than a short, straight one. Damaged or squashed hose has the same effect, and flexible hose adds more resistance than smooth rigid duct.

    Ducting should be free from acute bends, kinks, holes and cracks, and long sections of flexible ducting should be avoided. In practice, use only the length you need, let the hose run in gentle curves, and replace any hose that is split or collapsed. The unit's manual will say which hose sizes it is designed for.

    Is a portable extractor with an arm enough, or do I still need respiratory protection?icon-minus-redicon-plus-red

    It depends on the job, but an extraction arm alone is not always enough. Respiratory protective equipment may be needed where extraction alone cannot provide adequate control, for example a movable hood on a flexible arm used on a large workpiece with long welds, where frequent repositioning means the fume control depends heavily on the welder.

    Local extraction is usually not a practical option when welding outdoors in the open air, and may not be practical when working at height, where respiratory protection is the alternative. Your risk assessment should decide what combination is needed, and the unit's manual and a competent person can help you set it up correctly.

    What does a particle filter cartridge do and when should it be replaced?icon-minus-redicon-plus-red

    The cartridge is the main filter in a fume extractor. It traps the very fine solid particles in welding fume so that the air leaving the unit is cleaner. As it loads up, airflow falls.

    The unit should have a suitable filter for welding fume that is regularly inspected and replaced when necessary, with an indicator or alarm to show if filters have blocked or failed. Replace on the signal from the unit or when suction drops, rather than purely by the calendar. Check the hose and hood for blockages first, then replace the cartridge if suction is still poor, using only the type the manual specifies.