ESAB Fume Extractors FAQs
Straight answers to the questions people ask most when choosing and using a portable welding fume extractor.
How close should the extraction nozzle be to the weld?

As close as you can get without interfering with the work, and positioned so the fume is drawn away from your face. Capture falls away quickly with distance, so a nozzle held too far from the arc captures very little.
Reposition it as you move along the joint. Take care that the airflow does not disturb the shielding gas around the weld, as that can cause defects. Check the manual for your own extractor for the recommended nozzle distance and position.
Will the extractor disturb my shielding gas?

It can, if the suction is too strong or the nozzle is too close and pointing straight at the arc. A disturbed gas shield causes porosity in the weld.
Place the nozzle to the side and slightly behind the weld, and adjust the distance and angle until the fume is captured without blowing the gas away. Test on scrap material first if the weld quality is critical.
How do I know when the filter needs changing?

Signs include weaker suction, a warning light or indicator if the unit has one, more visible fume escaping, and a noticeable rise in the noise of the motor as airflow drops. A blocked filter reduces capture, so the unit looks as if it is working but protects you less.
Follow the maker's guidance on checking and changing filters. Handle used filters carefully, as they contain the welding fume that has been collected, and dispose of them as the regulations for your waste require.
Does a portable extractor remove the need for a respirator?

Not automatically. Source extraction reduces your exposure, but it may not remove the hazard completely, especially in confined or awkward positions or with some materials. Whether you also need respiratory protection depends on your risk assessment, the material, the process and the fume levels.
The HSE treats all welding fume, including mild steel fume, as a cause of lung cancer, so suitable controls must be in place and checked. Use extraction as one part of your controls, and follow the HSE guidance on welding fume.