WE HAVE SOME GREAT LIMITED-TIME OFFERS - CLICK HERE TO VIEW THEM WE SHIP WORLDWIDE    /    All UK ORDERS GREATER THAN £75 EX VAT DELIVERED FREE    /    WE SHIP WORLDWIDE    /    ALL EUROPEAN ORDERS GREATER THAN £500.00 ex VAT DELIVERED FREE    /    WE SHIP WORLDWIDE
    Share this page on Facebook   Share this page on LinkedIn   Share this page on Twitter   Share this page on Whatsapp   

    Rapid Ref : MONOGO-PLUS  

    Plymovent MonoGo Plus Stationary Filter Unit with KUA Extraction Arm
    MONOGO-PLUS

    Select Option 
    Prices From £2173.00 ex VAT

    The MonoGo Plus is a stationary welding fume filter with built in fan and KUA metal tube arm. It contains a disposable HEPA filter cassette. The MonoGo Plus has been designed for occasional to regular welding activities (approximately 2 coils of solid wire or 15Kg /33lbs of electrodes per month) and TIG welding.

    Brochures & Manuals

    Related Items

    Plymovent Stationary Filter Units FAQs

    Straight answers to the questions people ask most when choosing and running stationary welding fume filter units.

    What is a stationary filter unit and where is it used?icon-minus-redicon-plus-red

    A stationary filter unit is a fixed fan and filter assembly that draws contaminated air from one or more extraction points, cleans it and either returns it to the workshop or discharges it. Sizes range from small units serving a single arm to central systems serving a whole workshop.

    They suit permanent welding stations, production lines, cutting tables and general fume and dust control.

    How do I decide on the size and airflow I need?icon-minus-redicon-plus-red

    Add up the airflow needed at every extraction point that will run at the same time, then allow for duct resistance and some margin. Arm length, hood size, the process and the number of welders all affect the figure.

    A unit that is too small will not capture fume properly, while one that is too large wastes energy. A system designer or the supplier can work through this with you, so ask our team to help you choose.

    Single-arm units, multi-arm units or a central system - which should I choose?icon-minus-redicon-plus-red

    A single unit with its own arm is simple and good for one station. Several arms on one unit work if the stations share a space and are not all used at once. A central system with ducting suits many stations and gives one place to maintain the filter.

    Central systems need more design work and ducting, and their balance matters, but they can be easier to look after in a large workshop.

    What electrical and compressed air connections are needed?icon-minus-redicon-plus-red

    Larger units normally need a three-phase supply, while smaller ones may run from single phase. Self-cleaning types need a supply of clean, dry compressed air at a stated pressure, unless the unit has its own compressor.

    The data plate and manual list the requirements. Electrical connection and air connections should be made by competent people, and the fan rotation should be checked at commissioning.