0 items in your basket
Total £ 0.00 EX VAT
Mobile Fume Extractors
Extraction Arms & Fans
Plymovent Extraction Fans
Plymovent Hose Tube Arms
Plymovent Metal Tube Arms
Plymovent Plastic Tube Arms
Plymovent Extraction Arm Accessories
Stationary Filter Units
Spark Arrestors
Extraction Tables
Control Equipment
FlexHood
Filters & Spare Parts
Extraction Arm Spare Parts
Stationary Filter Unit Spares
Mobile Filter Unit Spares
Plymovent Fan Spares
Plymovent Extraction Table Spare Parts
Plymovent Filters
Environment Diluter System
Easy Solutions For Source Extraction
Mobile / Portable Solutions
Stationary Solutions
Stationary Solutions with Filter Units
Downdraft Tables
Machine Tool Applications
RPE Air Fed Helmets
Aeroguard Air Quality Monitor
Shop 55,000 Products
SERVICEDEPT.
RAPID BLOG
FEEDBACK
HIRE
Straight answers to the questions people ask most about spare parts for a two-filter cartridge extraction unit with a dust container.
Use the data plate on the unit for the model and serial number, then match the part against your manual or parts list. Dust containers, lids, seals, holders and cover plates differ between units and between sizes, so appearance alone can mislead.If you are not sure, send photographs of the old part and the data plate to our team.
Filter cartridges are the main consumable. Lid and cover seals, drain valves, clamps and knobs, relays and fuses, and the feet or trolley of the dust container also wear or get damaged in use.A failing seal lets unfiltered air leak, and a worn electrical part may stop the unit starting or cause nuisance trips.
Falling suction at the extraction point, more fume or dust in the workshop, or an indicator showing high resistance across the filter are the signs. How often depends on how much and what kind of fume or dust the unit handles.Follow the maker's guidance, and change the filters before they block completely, as a clogged filter strains the fan.
It depends on the unit, so follow the manual for your own machine. In a unit with more than one filter, the air divides between them, and a filter that has been in use for a while resists the flow more than a new one. Mixing new and old filters can therefore load them unevenly.Some makers advise changing filters as a set, while others allow them to be changed individually when each is monitored separately. Check the data plate, the manual and the filter condition indicator for your unit, and ask our team if the guidance is unclear.
The lid seal makes the container airtight, so that the suction inside the unit is maintained and dust cannot escape when the container is full. A worn, hard or flattened seal lets in false air, which reduces performance, and may release dust.Check the seal whenever you empty the container, and replace it if it is damaged or no longer seals evenly.
Empty it before it becomes full, not after. An overfull container can block the flow and may let dust back into the filter. How often depends on how much dust you produce.Wear respiratory protection and gloves, avoid shaking the contents into the air, bag the waste, and dispose of it in line with your risk assessment.