0 items in your basket
Total £ 0.00 EX VAT
Mobile Fume Extractors
Extraction Arms & Fans
Plymovent Extraction Fans
Plymovent Hose Tube Arms
Plymovent Metal Tube Arms
Plymovent Plastic Tube Arms
Plymovent Extraction Arm Accessories
Stationary Filter Units
Spark Arrestors
Extraction Tables
Control Equipment
FlexHood
Filters & Spare Parts
Extraction Arm Spare Parts
Stationary Filter Unit Spares
Mobile Filter Unit Spares
Plymovent Fan Spares
Plymovent Extraction Table Spare Parts
Plymovent Filters
Environment Diluter System
Easy Solutions For Source Extraction
Mobile / Portable Solutions
Stationary Solutions
Stationary Solutions with Filter Units
Downdraft Tables
Machine Tool Applications
RPE Air Fed Helmets
Aeroguard Air Quality Monitor
Shop 55,000 Products
SERVICEDEPT.
RAPID BLOG
FEEDBACK
HIRE
Straight answers to the questions people ask most when choosing replacement parts for a fume extraction arm.
These are replacement parts for a particular type of fume extraction arm: hoses, inner and outer tubes, frames, hoods, hood collars, joints, connection flanges and fixings.They let you repair a damaged arm instead of replacing the whole thing, and keep your extraction working properly at the point of capture.
Check the data plate on the arm for its type and size, then look in the manual or parts list for the part number or description. Arms usually come in several lengths, so tubes and frames differ by size.Measure the hose diameter and length, and note which end of the arm the part belongs to. Our team can help you choose if you send a photo.
Replace it if you find splits, cracks, holes, crushed or kinked sections, heavy wear or a stiff, brittle feel. Loose or damaged clamps also let air escape.A damaged hose cuts suction at the hood, so fume is captured less well and the extraction unit has to work harder. Replace it promptly instead of taping it.
Loss of capture has several possible causes, so work through them in turn. Check the hose and joints for splits, kinks or loose clamps, then the hood and any grid for clogging, then the damper position, and then the filter or filter indicator at the extraction unit. Also make sure the hood is close to the weld, as capture falls away quickly with distance.If you cannot find the cause, check the manual for your own machine for the airflow it should achieve, and have the system tested by a competent person. HSE guidance expects extraction to be kept in good repair and thoroughly examined at regular intervals.
Many arms have a damper, a flap or valve at or near the hood, that lets you adjust or shut off the airflow through that arm. Where several arms share one fan, the system is normally balanced when it is commissioned so each arm gets the flow it needs, so do not change damper settings without checking the manual or the system designer's instructions.If the damper sticks, will not stay in position or no longer seals, check the data plate and parts list for your own arm to find the correct replacement.
A mesh or grid on the hood or flange stops larger objects, sparks and debris being drawn into the arm and ductwork.Keep it clean and in place. A clogged or damaged mesh reduces airflow and should be cleaned or replaced.