0 items in your basket
Total £ 0.00 EX VAT
Mobile Fume Extractors
Extraction Arms & Fans
Plymovent Extraction Fans
Plymovent Hose Tube Arms
Plymovent Metal Tube Arms
Plymovent Plastic Tube Arms
Plymovent Extraction Arm Accessories
Stationary Filter Units
Spark Arrestors
Extraction Tables
Control Equipment
FlexHood
Filters & Spare Parts
Extraction Arm Spare Parts
Stationary Filter Unit Spares
Mobile Filter Unit Spares
Plymovent Fan Spares
Plymovent Extraction Table Spare Parts
Plymovent Filters
Environment Diluter System
Easy Solutions For Source Extraction
Mobile / Portable Solutions
Stationary Solutions
Stationary Solutions with Filter Units
Downdraft Tables
Machine Tool Applications
RPE Air Fed Helmets
Aeroguard Air Quality Monitor
Shop 55,000 Products
SERVICEDEPT.
RAPID BLOG
FEEDBACK
HIRE
The WallPro has a unique set of features that provide real benefits:
Straight answers to the questions people ask most when choosing and running stationary welding fume filter units.
A stationary filter unit is a fixed fan and filter assembly that draws contaminated air from one or more extraction points, cleans it and either returns it to the workshop or discharges it. Sizes range from small units serving a single arm to central systems serving a whole workshop.They suit permanent welding stations, production lines, cutting tables and general fume and dust control.
A single unit with its own arm is simple and good for one station. Several arms on one unit work if the stations share a space and are not all used at once. A central system with ducting suits many stations and gives one place to maintain the filter.Central systems need more design work and ducting, and their balance matters, but they can be easier to look after in a large workshop.
Often yes, if the filter is rated for the fume and the process does not give off hazardous gases or vapours the filter cannot remove. Returning air saves heating energy and avoids drawing cold air in through the building.Check the manufacturer's guidance and your risk assessment. Stainless steel, coated materials and some consumables need extra care, and some applications require discharge to the outside instead.
Larger units normally need a three-phase supply, while smaller ones may run from single phase. Self-cleaning types need a supply of clean, dry compressed air at a stated pressure, unless the unit has its own compressor.The data plate and manual list the requirements. Electrical connection and air connections should be made by competent people, and the fan rotation should be checked at commissioning.