MDB-2F Spare Parts FAQs
Straight answers to the questions people ask most about spare parts for a two-filter cartridge extraction unit with a dust container.
How do I identify the correct spare for my extraction unit?

Use the data plate on the unit for the model and serial number, then match the part against your manual or parts list. Dust containers, lids, seals, holders and cover plates differ between units and between sizes, so appearance alone can mislead.
If you are not sure, send photographs of the old part and the data plate to our team.
Should both filters be changed together?

It depends on the unit, so follow the manual for your own machine. In a unit with more than one filter, the air divides between them, and a filter that has been in use for a while resists the flow more than a new one. Mixing new and old filters can therefore load them unevenly.
Some makers advise changing filters as a set, while others allow them to be changed individually when each is monitored separately. Check the data plate, the manual and the filter condition indicator for your unit, and ask our team if the guidance is unclear.
What does the dust container lid seal do?

The lid seal makes the container airtight, so that the suction inside the unit is maintained and dust cannot escape when the container is full. A worn, hard or flattened seal lets in false air, which reduces performance, and may release dust.
Check the seal whenever you empty the container, and replace it if it is damaged or no longer seals evenly.
What is the drain valve for?

Some units collect moisture or condensation, and the drain valve lets you release it from the system. A valve that is stuck, leaking or corroded can cause damp in the container, which clumps dust and can damage the filters.
Check it periodically and replace it if it does not close properly.