Plymovent Filters FAQs
Straight answers to the questions people ask most when choosing replacement filters for welding fume extraction systems.
How do I choose the correct replacement filter for my extraction unit?

Use the unit's data plate and manual to identify the exact filter type and size. Filters vary in shape, media, surface area and sealing method, and units are designed around a specific filter.
Never choose by appearance alone. Note the filter's reference and dimensions from the old one, and ask our team if you cannot identify it.
Why should I avoid generic replacement filters?

A filter is a key part of the system's performance. A filter that differs in size, media or sealing can reduce airflow, let fume bypass the media, or stop automatic cleaning from working properly.
That can mean poor protection for people and damage to the unit. Use a filter specified for your unit unless the manufacturer confirms an alternative.
How do I know when a filter needs replacing?

Most units have a pollution indicator or pressure gauge that shows when the filter is loaded. Other signs are weaker suction at the hood, more frequent cleaning cycles, and more dust or smell in the workshop.
Change the filter when the indicator says so or if airflow cannot be restored by cleaning. Keep a record of change dates to help plan.
What is the difference between cartridge, cassette and bag filters?

These are different filter formats, and the names vary between makers. Cartridge filters are usually pleated tubes giving a large filtering surface in a compact space, and are often cleaned by pulses of air. Bag filters are fabric pockets, and panel or cassette types are flat elements.
The unit is designed around one format, so the data plate and manual for your own machine will tell you which type and size fits. Each has its own fitting and cleaning method.